Electromagnetic Thickness Tools
Applications
- Measure the remaining wall thickness or metal loss
- Determination of the damage type like pits, transversal/longitudinal cracks
- Determination of inner casing penetration
- Locating casing collars
- Metal Loss Inspection
- Wall Thickness Measurement
- 3D Imaging of Well Condition
- Pits Detection
Features
- 175℃, 100MPa
- OD 1 11/16"(43mm)
- SRO/memory modes
- Dual coil receiver with high sensitivity and signal-noise ratio
- Extensible spring arms closer to wall for better measuring performance
- Small temperature drift, strong anti-interference capability
Benefits
- Dual coil receiver with high sensitivity and signal-noise ratio
- Small temperature drift, strong anti-interference capability
Our Electromagnetic Thickness Tools (EMT) have been designed to measure casing wall thickness. The power is supplied and the signals are transmitted through mono-conductor cable.
The EMT includes an array of miniature sensors. Each sensor obtains one magnetic variation signal. All of the data from the twelve sensors are transmitted through the telemetry cartridge to the surface to be presented in log records.
The EMT must be centralized during operation, and combined use with the multi-finger caliper is recommended. Special interpretation software is provided for interpretation of EMT data only or for combined interpretation of EMT and multifinger caliper measurements. Three-dimensional imaging and outout may be realized.
EMT 16
Utilizes 12 padded sensors to determine the exact location of damage and pitting in a single string of casing.
EMT 24
Measures remaining wall thickness in multi-casing applications in a single run.